Robot cell troubleshooting

A robot cell with a hidden fault — some stop the line, the dangerous ones don't. Work the panel, read the robot, and name the fault.

Result

Fault in the field

Nothing ruled out yet — the PLC view below is live.

What the PLC sees — output bits

CELL SAFE light0
Robot — PROG echo0
status bitsRDY 0 · BUSY 0 · DN 0 · FLT 0
Online ladder — what the PLC is COMMANDING
RESETSAFETY OKE-STOPGATE CH AGATE CH BSAFETY OK0 — Dual-channel gate and e-stop seal the safety relay; RESET is the only way inSAFETY OKRB1.ENRB1.P1CELL SAFEdevice: stopped1 — Safety OK enables the robot, picks program 1 and lights the cellCYCLE STARTRB1.RDYRB1.START2 — CYCLE START is gated by READYCURTAINRB1.HOLD3 — The curtain only HOLDs - presence sensing pauses, it does not break the chainFAULT RSTSAFETY OKRB1.RST

A lit coil is an order, not proof the machine moved. Under each coil is what that device is physically doing — when the two disagree, the break is past the output card.

Call it — name the component and how it failed

Open contact, broken wire or loose terminal — the PLC never sees it actuate.

Formula sources: Standard I/O troubleshooting method: compare commanded state (logic) against actual state (field) at each interface

A training simulator — on a real panel, faults involve live voltage. Follow lockout/tagout, verify with a meter (not with your fingers), and never bypass a safety circuit to make a machine run.