Wall framing takeoff

Count studs and plates for a wall — corners, T-intersections and openings included — with every line of the count shown.

Result

30 studs
27 counted + 10% waste
Straight run (16" OC)19
Corners ×2 (+2 each)+4
Openings ×1 (2 kings + 2 jacks each)+4
Plates — double top + bottom72 lin ft

Headers and cripples for the opening are extra cut stock — sized by the opening width, not counted here.

The wall, stud by stud
opening ×116" OC24 ft

Formula sources: Standard platform-framing conventions: 16/24 in OC layout, 3-stud corners, king + jack per opening side

A material takeoff, not a framing plan: bearing walls, shear panels, tall-wall studs, and header sizes come from your plans and code (IRC R602). Local practice on corners and backing varies — adjust the extras to match yours.